Re: [hylafax-users] Failure to receive silence
On Wed, 20 Aug 2003 11:36:18 +0300, Andrey Adamovich <adamovich@solcraft.lv>
wrote:
>in the end of the log I get "Failure to receive silence"
>I was reading news groups and mailing lists
>and found that adding a line
>Class1SwitchingCmd: "<delay:7>"
>Here goes some log information:
>Aug 19 14:07:39.47: [16317]: RECV recv EOP (no more pages or
>documents)
>Aug 19 14:07:39.47: [16317]: <-- [9:AT+FRS=7\r]
>Aug 19 14:08:09.47: [16317]: MODEM <Timeout>
Probably you didn't restart faxgetty or used wrong config since HylaFAX
keeps using +frs.
--