On 2003.08.04 22:39 kengheng wrote: > Aug 05 12:41:16.28: [ 3832]: <-- [10:AT+FTM=96\r] > Aug 05 12:41:16.30: [ 3832]: --> [7:CONNECT] > Aug 05 12:41:18.65: [ 3832]: <-- [10:AT+FTM=72\r] > Aug 05 12:41:18.66: [ 3832]: --> [7:CONNECT] > Aug 05 12:41:21.09: [ 3832]: <-- [10:AT+FTM=48\r] > Aug 05 12:41:21.11: [ 3832]: --> [7:CONNECT] > Aug 05 12:41:23.70: [ 3832]: <-- [10:AT+FTM=24\r] > Aug 05 12:41:23.72: [ 3832]: --> [7:CONNECT] Notice how quickly we get CONNECT after +FTM=x (20 ms). Older Rockwells can take ten times as long. This quick CONNECT is actually according to T.31 spec (don't ask me why). In these cases we need to use Class1TMConnectDelay. http://bugs.hylafax.org/bugzilla/show_bug.cgi?id=419 It may help. Lee. ____________________ HylaFAX(tm) Users Mailing List _______________________ To subscribe/unsubscribe, click http://lists.hylafax.org/cgi-bin/lsg2.cgi On UNIX: mail -s unsubscribe hylafax-users-request@hylafax.org < /dev/null *To learn about commercial HylaFAX(tm) support, mail sales@hylafax.org.*