On 2002.07.29 03:50 Marius wrote: > >>> Jul 26 20:45:23.03: [28713]: SEND training at v.29 9600 bit/s >>> Jul 26 20:45:23.03: [28713]: <-- [9:AT+FTH=3\r] >>> Jul 26 20:45:23.15: [28713]: --> [7:CONNECT] >>> Jul 26 20:45:23.88: [28713]: --> [7:CONNECT] >>> Jul 26 20:45:25.23: [28713]: --> [2:OK] >> >> Try and contact Eicon to see why the modem is doing this. >> >> It is not reporting OK until after nearly two seconds and after *two* >> CONNECTs. That's a problem that only Eicon can fix (firmware issue). >> We may be able to provide a workaround once we know exactly what the >> matter is. > > This is an internal Eicon Server board and apparently there isn't any > firmware. Huh? There's no firmware? Then where's the logic that knows what to do with "AT+FTH=3" in the first place? > The connection to this particular machine seems to managed by a > faxselector. Would it be possible that this is the cause of the errors. Possibly the catalyst, but I don't know. The "cause" of the *error* however, is the modem firmware. > However, I'm told that normal faxmachines don't have problems connecting. Of course, at least "normal faxmachines" without said firmware bug. > We had this problem with more connections to faxmachines, but switching > to Class 1 and disabling Error Correction resolved (most of) these > issues. "This problem" can only exist in Class 1. Lee. ____________________ HylaFAX(tm) Users Mailing List _______________________ To subscribe/unsubscribe, click http://lists.hylafax.org/cgi-bin/lsg2.cgi On UNIX: mail -s unsubscribe hylafax-users-request@hylafax.org < /dev/null *To learn about commercial HylaFAX(tm) support, mail sales@hylafax.org.*