Hi, Here is my working config file for US Robotics 14.4 modem Best regards, Siew Massimo Donato writes: > Sorry First one without config attached. > > Hi, > Here is my config file for my usr 56k faxmodem, just a bit different > from your. > I used Class 1 config because of higher error rates in Class 2. > > I removed the FAXNumber and Local Identifier fileds, i think you want to > edit them. > > regards. > > Massimo Donato > > > ----- Original Message ----- > From: "Alain Siani" <ASiani@wanadoo.fr> > To: "List Hylafax" <hylafax-users@hylafax.org> > Sent: Friday, June 21, 2002 1:05 PM > Subject: [hylafax-users] USR ROBOTIC > > >> Hello, >> >> if you have a config for USR ROBOTIC 56K MESSAGE, please send me your >> hylafax config file... >> >> Thks >> Alain >> >> >> >> ____________________ HylaFAX(tm) Users Mailing List > _______________________ >> To subscribe/unsubscribe, click > http://lists.hylafax.org/cgi-bin/lsg2.cgi >> On UNIX: mail -s unsubscribe hylafax-users-request@hylafax.org < > /dev/null >> >
# $Id: usr-xon,v 1.6 2002/04/07 20:29:27 darren Exp $ # # HylaFAX Facsimile Software # # Copyright (c) 1990-1996 Sam Leffler # Copyright (c) 1991-1996 Silicon Graphics, Inc. # HylaFAX is a trademark of Silicon Graphics, Inc. # # Permission to use, copy, modify, distribute, and sell this software and # its documentation for any purpose is hereby granted without fee, provided # that (i) the above copyright notices and this permission notice appear in # all copies of the software and related documentation, and (ii) the names of # Sam Leffler and Silicon Graphics may not be used in any advertising or # publicity relating to the software without the specific, prior written # permission of Sam Leffler and Silicon Graphics. # # THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND, # EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY # WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. # # IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR # ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND, # OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS, # WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF # LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE # OF THIS SOFTWARE. # # # Configuration for using the Class 1 command interface with # a USR Courier or Sportster modem and XON/XOFF flow control. # # CONFIG:CLASS1:1444:.*:XON*|DEF*: Manufacturer=USRobotics Model=Courier/Sportster # CONFIG:CLASS1:1445:.*:XON*|DEF*: Manufacturer=USRobotics Model=Courier/Sportster # CONFIG:CLASS1:2886:.*:XON*|DEF*: Manufacturer=USRobotics Model=Courier/Sportster # CONFIG:CLASS1:3366:.*:XON*|DEF*: Manufacturer=USRobotics Model=Courier # CONFIG:CLASS1:3361:.*:XON*|DEF*: Manufacturer="USRobotics w/TI Chipset" Model="Sportster 33600" # CONFIG:CLASS1:3362:.*:XON*|DEF*: Manufacturer="USRobotics w/TI Chipset" Model="Sportster 33600" # CONFIG:CLASS1:3367:.*:XON*|DEF*: Manufacturer="USRobotics" Model="Courier" # CONFIG:CLASS1:5601:.*:XON*|DEF*: Manufacturer="3Com U. S. Robotics" Model="3CP5610" # # BEGIN-SERVER CountryCode: 60 AreaCode: 03 FAXNumber: +60.03.78773629 LongDistancePrefix: 00 InternationalPrefix: 000 DialStringRules: etc/dialrules ServerTracing: 11 SessionTracing: 11 RecvFileMode: 0644 LogFileMode: 0644 DeviceMode: 0666 RingsBeforeAnswer: 1 #SpeakerVolume: off GettyArgs: "-h %l dx_%s" LocalIdentifier: "NothingSetup" TagLineFont: etc/lutRS18.pcf TagLineFormat: "From %%l|%c|Page %%P of %%T" MaxRecvPages: 25 # END-SERVER # # Modem-related stuff: should reflect modem command interface # and hardware connection/cabling (e.g. flow control). # ModemType: Class1 # use class 1 interface ModemRate: 19200 # rate for DCE-DTE communication ModemFlowControl: xonxoff # hardware flow control # #ModemSetupDTRCmd: ATS13=1&D2 # setup so DTR drop resets modem ModemSetupDCDCmd: AT&W1 # setup so DCD reflects carrier (or not) #ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier (or not) ModemNoFlowCmd: AT&H0&I0&R1 # setup modem for no flow control ModemHardFlowCmd: AT&H1&I0&R2 # setup modem for hardware flow control #ModemSoftFlowCmd: AT&H2&I2&R1 # setup modem for software flow control #ModemResultCodesCmd: ATQ0X4 # enable result codes # ModemMfrQueryCmd: !USR ModemModelQueryCmd: ATI3 ModemRevQueryCmd: ATI7 # XXX returns a multi-line result # # When AT+FCLASS=1 is issued the modem automatically switches # to software flow control; these parameters let the fax software # reset flow control as needed after entering Class 1. # Class1NFLOCmd: AT&H0&I0&R1 # setup modem for no flow control Class1HFLOCmd: AT&H1&I0&R2 # setup modem for hardware flow control Class1SFLOCmd: "" # modem does this automatically # # The remainder of this configuration is included so that the # modem "idles" in Class 0 while not sending or receiving facsimile. # #ModemSetupAACmd: AT+FCLASS=0 # leave modem idling in class 0 ModemAnswerCmd: AT+FCLASS=1A # answer in Class 1 # # Disables the reporting of bad frames by the modem. This # overcomes a firmware problem in the x2 and V90 Sportsters. # It is not necessary for the Courier modem. # Class2NRCmd: AT+FNR=1,1,1,0 ModemSetVolumeCmd: AT&W1