Re: [hylafax-users] Receive problems with ELSA 28.8 TQV
Hi Michael, use hardware flow control not xon/xoff
I attached my working config-file
don't forget to change your identifier and so on
(dialcmd is set for pabx)
HIH
Matthias
> Hi!
>
> May be any one could give me a clue? I have configured my TKR TriStar
> (which should be identical to the ELSA 28.8 TQV) as described by Michael
> Möller in http://www.hylafax.org/archive/1998-06/msg00010.php
> Seems to work fine, no errors reported in SysLog. When I start to send a
> fax to that modem via my ISDN card (in analogue mode) the call is
> received but after the first 4096 Byte is simply stops until the modem
> is set back (ISDN error code is 3114 => connection aborted by receiver).
> SysLog shows:
> Aug 23 15:02:41 gandalf FaxGetty[1335]: MODEM "" "TKR TriStar"/"Ver.
> 1.10 vom 19.09.95"
> Aug 23 15:03:46 gandalf FaxGetty[1335]: ANSWER: FAX CONNECTION
> Aug 23 15:04:23 gandalf FaxGetty[1335]: MODEM "" "TKR TriStar"/"Ver.
> 1.10 vom 19.09.95"
> logging is set to local7
> I can't figure out what is wrong. When I use my USR Courier V.Everything
> there is no problem in receiving via my ISDN card, so I guess this could
> be a problem of my configuration - what? :-((
>
> Any help appreciated - TIA :-)
>
> Maybe it helps to post my config file:
>
> --------------- soc - start of cut ---------------------
> CountryCode: 49
> AreaCode: 511
> FAXNumber: +49.511.
> LongDistancePrefix: 0
> InternationalPrefix: 00
> DialStringRules: etc/dialrules
> ServerTracing: 1
> SessionTracing: 11
> RecvFileMode: 0644
> LogFileMode: 0600
> DeviceMode: 0600
> RingsBeforeAnswer: 1
> SpeakerVolume: off
> GettyArgs: "-h %l dx_%s"
> LocalIdentifier: "+49.511."
> LogFacility: local7
> TagLineFont: etc/lutRS18.pcf
> TagLineFormat: "Von %%l|%c|Seite %%p von %%t"
> PercentGoodLines: 80
> MaxConsecutiveBadLines: 20
> MaxRecvPages: 250
> ModemPriority: 200
> #
> #
> # Modem-related stuff: should reflect modem command interface
> # and hardware connection/cabling (e.g. flow control).
> #
> ModemType: Class2.0 # use this to supply a hint
> ModemRate: 19200 # max rate for DCE-DTE
> communication
> ModemFlowControl: xonxoff # XON/XOFF flow control assumed
> ModemSetupDTRCmd: AT&D2 # setup so DTR drop resets modem
> ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier
> (or not)
> #
> # We normally append the "@" symbol to the dial string so that
> # the modem will wait 5 seconds before attempting to connect
> # and return result codes that distinguish between no carrier
> # and no answer. This makes it possible to avoid problems with
> # repeatedly dialing a number that doesn't have a fax machine
> # (kudos to Stuart Lynne for this trick.)
> #
> # NB: If you need to prefix phone numbers to get through a PBX,
> # put it in the ModemDialCmd; e.g. "DT9%s@".
> #
> ModemDialCmd: ATDT%s
> #
> # Other possible configuration stuff. The default strings are
> # shown below. Only those that are different from the defaults
> # need to be included in the configuration file.
> #
> ModemResetCmds: ATX3S130=68 # stuff to do when modem is
> reset
> ModemAnswerCmd: ATA # use this to answer phone
> ModemNoFlowCmd: AT\Q0
> ModemHardFlowCmd: AT\Q3
> ModemSoftFlowCmd: AT\Q4
> ModemNoAutoAnswerCmd: ATS0=0 # disable auto-answer
> #
> # Set modem speaker volume commands: OFF QUIET LOW MEDIUM HIGH.
> # Note that we both turn the speaker on/off and set volume.
> #
> ModemSetVolumeCmd: "ATM0 ATL0M1 ATL1M1 ATL2M1 ATL3M1"
> ModemEchoOffCmd: ATE0 # disable command echo
> ModemVerboseResultsCmd: ATV1 # enable verbose command results
> ModemResultCodesCmd: ATQ0 # enable result codes
> ModemOnHookCmd: ATH0 # place phone on hook (hangup)
> ModemSoftResetCmd: ATZ # do soft reset of modem
> ModemWaitTimeCmd: ATS7=60 # wait 60 seconds for carrier
> ModemCommaPauseTimeCmd: ATS8=2 # comma pause time is 2 seconds
> ModemRecvFillOrder: LSB2MSB # bit order of received
> facsimile
> ModemSendFillOrder: LSB2MSB # bit order modem expects for
> transmit
> #
> # Configuration parameters for Class 2.0 modems.
> #
> Class2Cmd: AT+FCLASS=2.0 # command to enter class 2.0
> Class2BORCmd: AT+FBO=0 # bit order for phase B/C/D
> (direct)
> Class2CQCmd: "" # commands to enable copy
> quality proc.
> Class2AbortCmd: AT+FKS # abort session command
> Class2CQQueryCmd: AT+FCQ=? # query for copy quality
> capabilities
> Class2DCCQueryCmd: AT+FCC=? # query for modem capabilities
> Class2TBCCmd: AT+FPP=0 # setup stream mode
> Class2CRCmd: AT+FCR=1 # enable capability to receive
> Class2PHCTOCmd: AT+FCT=30 # set phase C timeout parameter
> Class2BUGCmd: AT+FBU=1 # enable HDLC frame tracing
> Class2LIDCmd: AT+FLI # set local identifier command
> Class2DCCCmd: AT+FCC # set modem capabilities command
> Class2DISCmd: AT+FIS # set session parameters command
> Class2DDISCmd: "" # disable pre-dial DIS command
> hack
> Class2CIGCmd: AT+FPI # set polling identifier command
> Class2NRCmd: AT+FNR=1,1,1,1 # setup status reporting command
> Class2PIECmd: AT+FIE=0 # disable interrupt-enable
> command
> Class2PTSCmd: AT+FPS # set post-page status command
> Class2SPLCmd: AT+FSP # set polling indicator command
> Class2NFLOCmd: AT+FLO=0 # set no flow control command
> Class2SFLOCmd: AT+FLO=1 # set software flow control
> command
> Class2HFLOCmd: AT+FLO=2 # set hardware flow control
> command
> --------------- eoc - end of cut ---------------------
>
>
>
>
> ____________________ HylaFAX(tm) Users Mailing List _______________________
> To unsub: mail -s unsubscribe hylafax-users-request@hylafax.org <
> /dev/null
--
HAGOS eG phone: +49 711 7880592
Matthias Reich fax: +49 711 7880599
Industriestr. 62 web: http://www.hagos.de
D-70565 Stuttgart mail: rei@hagos.de
Germany
# $Id: class2,v 1.23 1996/06/24 02:58:32 sam Rel $
#
# HylaFAX Facsimile Software
#
# Copyright (c) 1990-1996 Sam Leffler
# Copyright (c) 1991-1996 Silicon Graphics, Inc.
# HylaFAX is a trademark of Silicon Graphics, Inc.
#
# Permission to use, copy, modify, distribute, and sell this software and
# its documentation for any purpose is hereby granted without fee, provided
# that (i) the above copyright notices and this permission notice appear in
# all copies of the software and related documentation, and (ii) the names of
# Sam Leffler and Silicon Graphics may not be used in any advertising or
# publicity relating to the software without the specific, prior written
# permission of Sam Leffler and Silicon Graphics.
#
# THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND,
# EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY
# WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
#
# IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
# ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
# OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
# WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF
# LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE
# OF THIS SOFTWARE.
#
#
# Generic Class 2 modem configuration.
#
# EDIT THIS CONFIGURATION TO REFLECT YOUR SETUP
#
CountryCode: 49
AreaCode: 711
FAXNumber: +49.XXXXXXXXXXXX
LongDistancePrefix: 0
InternationalPrefix: 00
DialStringRules: etc/dialrules
ServerTracing: 0
SessionTracing: 0
RecvFileMode: 0600
LogFileMode: 0600
DeviceMode: 0600
RingsBeforeAnswer: 1
SpeakerVolume: off
GettyArgs: "-h %l dx_%s"
LocalIdentifier: "Meine Firma"
TagLineFont: etc/lutRS18.pcf
TagLineFormat: " Von %%l|%c|Seite %%p von %%t"
QualifyTSI: etc/tsi
MaxRecvPages: 25
#
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType: Class2 # use this to supply a hint
ModemRate: 38400
ModemFlowControl: rtscts
ModemSetupDTRCmd: AT&D2 # setup so DTR drop resets modem
ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier (or not)
#
# We normally append the "@" symbol to the dial string so that
# the modem will wait 5 seconds before attempting to connect
# and return result codes that distinguish between no carrier
# and no answer. This makes it possible to avoid problems with
# repeatedly dialing a number that doesn't have a fax machine
# (kudos to Stuart Lynne for this trick.)
#
# NB: If you need to prefix phone numbers to get through a PBX,
# put it in the ModemDialCmd; e.g. "DT9%s@".
#
ModemDialCmd: ATDT0,%s
#
# Other possible configuration stuff. The default strings are
# shown below. Only those that are different from the defaults
# need to be included in the configuration file.
#
ModemResetCmds: ATX3 # stuff to do when modem is reset
ModemAnswerCmd: ATA # use this to answer phone
ModemNoFlowCmd: AT\Q0 # disable flow control cmd
ModemHardFlowCmd: AT\Q3 # hardware flow control cmd
ModemSoftFlowCmd: AT\Q1 # software flow control cmd
ModemNoAutoAnswerCmd: ATS0=0 # disable auto-answer
#
# Set modem speaker volume commands: OFF QUIET LOW MEDIUM HIGH.
# Note that we both turn the speaker on/off and set volume.
#
ModemSetVolumeCmd: "ATM0 ATL0M1 ATL1M1 ATL2M1 ATL3M1"
ModemEchoOffCmd: ATE0 # disable command echo
ModemVerboseResultsCmd: ATV1 # enable verbose command results
ModemResultCodesCmd: ATQ0 # enable result codes
ModemOnHookCmd: ATH
ModemSoftResetCmd: ATZ # do soft reset of modem
ModemWaitTimeCmd: ATS7=60 # wait 60 seconds for carrier
ModemCommaPauseTimeCmd: ATS8=2 # comma pause time is 2 seconds
ModemRecvFillOrder: LSB2MSB # bit order of received facsimile
ModemSendFillOrder: LSB2MSB # bit order modem expects for transmit
#
# Configuration parameters for Class 2 modems.
#
Class2Cmd: AT+FCLASS=2 # command to enter class 2
Class2BORCmd: AT+FBOR=0 # bit order for phase B/C/D (direct)
Class2RELCmd: AT+FREL=1 # byte-align EOL codes on recv
Class2CQCmd: "" # commands to enable copy quality proc.
Class2AbortCmd: AT+FK # abort session command
Class2CQQueryCmd: AT+FCQ=? # query for copy quality capabilities
Class2DCCQueryCmd: AT+FDCC=? # query for modem capabilities
Class2TBCCmd: AT+FTBC=0 # setup stream mode
Class2CRCmd: AT+FCR=1 # enable capability to receive
Class2PHCTOCmd: AT+FPHCTO=30 # set phase C timeout parameter
Class2BUGCmd: AT+FBUG=1 # enable HDLC frame tracing
Class2LIDCmd: AT+FLID # set local identifier command
Class2DCCCmd: AT+FDCC # set modem capabilities command
Class2DISCmd: AT+FDIS # set session parameters command
Class2DDISCmd: "" # disable pre-dial DIS command hack
Class2CIGCmd: AT+FCIG # set polling identifier command
Class2PTSCmd: AT+FPTS # set post-page status command
Class2SPLCmd: AT+FSPL # set polling indicator command
#
# If Class2RecvDataTrigger is not set, then it is set to DC1
#
Class2RecvDataTrigger: "" # character sent to modem to start recv
Class2XmitWaitForXON: yes # if true, wait for XON before send