Re: [hylafax-users] AW: Frequent transmission breakdowns HF4.1 undHF4.1b3
At 07:01 AM 7/18/01 +0200, Peter Bauer wrote:
....
>Jul 18 06:46:02.71: [12852]: REMOTE NSF "00 00 11 90 00 85 57 10 49 54 53
45 52 56 20 47 4D 42 48 20 20 20 20 20 01 0C 01 0A 00 2C 00 80 91 80 02 01
01 4A"
>Jul 18 06:46:02.71: [12852]: NSF remote fax equipment: Canon
....
>Jul 18 06:46:09.32: [12852]: SEND end page
>Jul 18 06:46:29.45: [12852]: --> [2:OK]
>Jul 18 06:46:29.45: [12852]: DELAY 95 ms
>Jul 18 06:46:29.55: [12852]: SEND send EOP (no more pages or documents)
>Jul 18 06:46:29.55: [12852]: <-- [9:AT+FTH=3\r]
>Jul 18 06:46:29.58: [12852]: --> [7:CONNECT]
>Jul 18 06:46:29.58: [12852]: <-- data [3]
>Jul 18 06:46:29.58: [12852]: <-- data [2]
>Jul 18 06:46:30.85: [12852]: --> [2:OK]
>Jul 18 06:46:30.85: [12852]: <-- [9:AT+FRH=3\r]
>Jul 18 06:46:31.33: [12852]: --> [7:CONNECT]
>Jul 18 06:46:32.30: [12852]: --> [2:OK]
>Jul 18 06:46:32.30: [12852]: SEND recv RTN (retrain negative)
Dmitry spent a lot of time with RTN issues in Class 1 and particularly with
Canon fax machines (which he considered broken). I believe that he
considered the issue to be resolved (fixed in 4.1-release). I think that
you need to investigate RTNHandlingMethod. See 'man hylafax-config'.
Lee.
____________________ HylaFAX(tm) Users Mailing List _______________________
To unsub: mail -s unsubscribe hylafax-users-request@hylafax.org < /dev/null