[hylafax-users] Line busy while it's not
Version: Hylafax4.1beta3
OS: NetBSD 1.5 (i386)
Modem: Zoom 14.4 Ex (AFES - V1510b - Rockwell RPI (TM) MODEM Z20)
Hi,
When trying to receive a fax (sent using Cheyenne Bitware on Win95, but
that's not the problem) I get a "0x8111: Phone is busy" error in Bitware and
the following one in log/c00000000x:
Jun 24 20:43:45.77: [ 218]: SESSION BEGIN 00000011 312077xxxxx
Jun 24 20:43:45.78: [ 218]: <-- [4:ATA\r]
Jun 24 20:46:45.79: [ 218]: ANSWER: Ring detected without successful
handshake
Jun 24 20:46:45.79: [ 218]: SESSION END
I am pretty sure that the line is NOT busy (modem is not at my house, but
the line is seldom used and it happens 100% of the time). Config file is
attached. What could be going wrong? Oh, faxstat says "Running and idle".
Regards,
Wouter
"I'm too lazy to make a signature..."
=================================
# Configuration for a Rockwell-based Class 1 modem.
# SupraFAX v.32bis firmware V1.200-C or newer
# (and others)
#
# This configuration file sets up the modem to run at 38.4
# and use RTS/CTS flow control by default.
#
#
CountryCode: 31
AreaCode: 20
FAXNumber: "+31 20 77xxxxx"
LongDistancePrefix: 0
InternationalPrefix: 00
DialStringRules: etc/dialrules.europe
ServerTracing: 1
SessionTracing: 11
RecvFileMode: 0644
LogFileMode: 0600
DeviceMode: 0660
RingsBeforeAnswer: 1
SpeakerVolume: off
GettyArgs: "std.%s"
LocalIdentifier: "NothingSetup"
TagLineFont: etc/lutRS18.pcf
TagLineFormat: "From %%l|%c|Page %%P of %%T"
MaxRecvPages: 25
#
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType: Class1 # use class 1 interface
ModemRate: 38400
ModemFlowControl: rtscts # default
#
ModemNoFlowCmd: AT: AT&K0 # disable flow
control cmd
ModemHardFlowCmd: AT&K3 # hardware flow control cmd
ModemSoftFlowCmd: AT&K4 # software flow control cmd
ModemSetupDTRCmd: AT&D3 # setup so DTR drop resets modem
ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier
(or not)
ModemSetupAACmd: AT+FAA=0 # in case modem supports Class 2
also
#
ModemMfrQueryCmd: !Rockwell # no way to query modem
ModemModelQueryCmd: !RC32ACL # not always right
ModemRevQueryCmd: ATI3
____________________ HylaFAX(tm) Users Mailing List _______________________