I think that i have found the solution of my problem !!! Yeah !
In my config, i have added :
ModemBaudRateDelay: 1000
It's the delay after setting baud rate.
This is configuration with this message for help an other user who
would have the same problem !!
An other question :
what is the maximum baud rate for Hylafax and this modem ? 38400 ? or more ?
CountryCode: 33
AreaCode: 04
FAXNumber: 0381000000
LongDistancePrefix: 0
InternationalPrefix: 00
DialStringRules: etc/dialrules
ServerTracing: 0x0f
SessionTracing: 11
RecvFileMode: 0600
LogFileMode: 0600
DeviceMode: 0600
RingsBeforeAnswer: 0
SpeakerVolume: off
GettyArgs: "-h %l dx_%s"
LocalIdentifier: "XXX"
TagLineFont: etc/lutRS18.pcf
TagLineFormat: "From %%l|%c|Page %%p of %%t"
PercentGoodLines: 85
MaxRecvPages: 25
#
ModemType: Class2.0
ModemRate: 19200
ModemFlowControl: rtscts
ModemNoFlowCmd: AT&H0&I0&R1
ModemHardFlowCmd: AT&H1&I0&R2
ModemSoftFlowCmd: AT&H2&I2&R1
ModemSoftFlowCmd: ""
ModemSetupDTRCmd: ATS13=1&D2
ModemSetupDCDCmd: AT&C1
ModemSetupAACmd: AT+FAA=1
ModemSetVolumeCmd: "ATM0 ATL0M1 ATL1M1 ATL2M1 ATL3M1"
Class2BUGCmd: AT+FBU=0
Class2CQQueryCmd: !(0),(0)
Class2NRCmd: AT+FNR=1,1,1,0
# Added by me
#JobReqBusy: 180
#JobNoanswer: 180
#JobNoCarrier: 180
#JobReqOther: 180
#NoCarrierRetrys: 1
#Use2D: yes
ModemBaudRateDelay: 1000
ModemDialCmd: ATDT%s
ModemResetCmds: ""
#ModemResetCmds: ATZ
ModemAnswerCmd: ATA
ModemNoAutoAnswerCmd: ATS0=0
ModemEchoOffCmd: ATE0
ModemVerboseResultsCmd: ATV1
ModemResultCodesCmd: ATQ0X4
ModemOnHookCmd: ATH0
ModemSoftResetCmd: ATZ
ModemWaitTimeCmd: ATS7=60
ModemCommaPauseTimeCmd: ATS8=2
ModemRecvFillOrder: LSB2MSB
ModemSendFillOrder: LSB2MSB
Class2Cmd: AT+FCLASS=2.0
Class2APQueryCmd: ""
Class2BORCmd: AT+FBO=0
Class2CQCmd: ""
#Class2CQCmd: AT+FCQ=0,0
Class2AbortCmd: AT+FKS
Class2DCCQueryCmd: AT+FCC=?
Class2TBCCmd: AT+FPP=0
Class2CRCmd: AT+FCR=1
Class2PHCTOCmd: AT+FCT=60
Class2LIDCmd: AT+FLI
Class2DCCCmd: AT+FCC
Class2DISCmd: AT+FIS
Class2DDISCmd: ""
Class2CIGCmd: AT+FPI
Class2PIECmd: AT+FIE=0
Class2PTSCmd: AT+FPS
Class2SPLCmd: AT+FSP
Class2NFLOCmd: AT+FLO=0
Class2SFLOCmd: AT+FLO=1
Class2HFLOCmd: AT+FLO=2
----- Original Message -----
>From: Dmitry Bely <dbely@mail.ru>
>To: Cédric Bole-Richard <c.bolerichard@fabi.fr>
>Cc: <hylafax-users@hylafax.org>
>Sent: Wednesday, Oct 25, 2000 2:12 PM
>Subject: Re: [hylafax-users] Courier I-Modem ISDN/V.34 Problem
>
>
> Cédric Bole-Richard <c.bolerichard@fabi.fr> writes:
>
> > OK, i have missed double quotes, but, always the problem with there.
> >
> > Oct 25 11:04:01 Srv_Fabi02 FaxGetty[15281]: OPEN /dev/ttyS0
> > Oct 25 11:04:01 Srv_Fabi02 FaxGetty[15281]: MODEM set DTR OFF
> > Oct 25 11:04:01 Srv_Fabi02 FaxGetty[15281]: DELAY 2600 ms
> > Oct 25 11:04:03 Srv_Fabi02 FaxGetty[15281]: MODEM set DTR ON
> > Oct 25 11:04:03 Srv_Fabi02 FaxGetty[15281]: MODEM set baud rate: 38400
baud,
> > input flow RTS/CTS, output flow RTS/CTS
> > Oct 25 11:04:03 Srv_Fabi02 FaxGetty[15281]: MODEM flush i/o
> > Oct 25 11:04:03 Srv_Fabi02 FaxGetty[15281]: <-- [4:ATZ\r]
> > Oct 25 11:04:08 Srv_Fabi02 FaxGetty[15281]: MODEM TIMEOUT: reading line
from modem
> > Oct 25 11:04:08 Srv_Fabi02 FaxGetty[15281]: MODEM <Timeout>
>
>
Are you *absolutely* sure that your minicom (which works as you claim)
configured the same way? The same port (/dev/ttyS0), the same speed (38400)
etc? Are you *absolutely* sure that your modem has no aliases (e.g.
/dev/modem), preventing the correct UUCP-style locking? Excuse me, but I
don't believe in miracles...
>
> Hope to hear from you soon,
> Dmitry
>
____________________ HylaFAX(tm) Users Mailing List _______________________
To unsub: mail -s unsubscribe hylafax-users-request@hylafax.org < /dev/null