Adam Bisbe wrote: > > Hi all: > > Can someone suggest a config file for: > > MULTITECH MT2834 > > thank you. > > ____________________ HylaFAX(tm) Users Mailing List _______________________ > To unsub: mail -s unsubscribe hylafax-users-request@hylafax.org < /dev/null these work fine for us the config.mt1432 is for the MT models the config.zdx is for the ZDX Models HIH /matthias -- HAGOS eG phone: +49 711 7880592 Matthias Reich fax: +49 711 7880599 Industriestr. 62 web: http://www.hagos.de D-70565 Stuttgart mail: rei@hagos.de Germany ---------------------------------------------------------------------------- Be careful your mail is read by the NSA too !!
# $Id: mt-1432,v 1.23 1996/06/24 02:58:36 sam Rel $ # # HylaFAX Facsimile Software # # Copyright (c) 1990-1996 Sam Leffler # Copyright (c) 1991-1996 Silicon Graphics, Inc. # HylaFAX is a trademark of Silicon Graphics, Inc. # # Permission to use, copy, modify, distribute, and sell this software and # its documentation for any purpose is hereby granted without fee, provided # that (i) the above copyright notices and this permission notice appear in # all copies of the software and related documentation, and (ii) the names of # Sam Leffler and Silicon Graphics may not be used in any advertising or # publicity relating to the software without the specific, prior written # permission of Sam Leffler and Silicon Graphics. # # THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND, # EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY # WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. # # IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR # ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND, # OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS, # WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF # LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE # OF THIS SOFTWARE. # # # Configuration for a Multi-Tech MT1432, MT224BA, and MT1932ZDX modems. # # MT1432 firmware rev 0307 I or newer # MT132BG rev 0109A # MT1932ZDX rev 0109H # # Note that MT1432 modems come in several varieties: # # MT1432BA uses Rockwell data pump # MT1432BA/A uses AT&T data pump # MT1432BG MT1432BA tweaked for German FCC # MT1432MK (for UK?) # # The modem has been tried with both XON/XOFF and RTS/CTS flow # control; this configuration is for hardware flow control. # # CountryCode: 49 AreaCode: 0711 FAXNumber: +49.711.7880549 LongDistancePrefix: 0 InternationalPrefix: 00 DialStringRules: "etc/dialrules" ServerTracing: 0 SessionTracing: 0 RecvFileMode: 0600 LogFileMode: 0600 DeviceMode: 0600 RingsBeforeAnswer: 3 SpeakerVolume: off GettyArgs: "-h %l dx_%s" LocalIdentifier: "HAGOS eG Stuttgart" TagLineFont: etc/lutRS18.pcf TagLineFormat: " Von %%n %%l|%c|Seite %%p von %%t" PercentGoodLines: 90 MaxConsecutiveBadLines: 10 MaxRecvPages: 25 # # # Modem-related stuff: should reflect modem command interface # and hardware connection/cabling (e.g. flow control). # ModemType: Class2 # use class 2 interface ModemRate: 38400 # lock rate for DCE-DTE communication ModemFlowControl: rtscts # default ModemResetCmds: AT&FX3 # ModemHardFlowCmd: AT&E4 # hardware flow control ModemSoftFlowCmd: AT&E5 # software flow control ModemSetupDTRCmd: AT&D3 # setup so DTR drop resets modem ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier (or not) ModemSetupAACmd: AT+FAA=1 # enable adaptive-answer in class 2 # # NB: some models get confused by the @ # ModemDialCmd: ATDT0,%s # Class2RecvDataTrigger: "\022" # character sent to modem to start recv
# $Id: class2,v 1.23 1996/06/24 02:58:32 sam Rel $ # # HylaFAX Facsimile Software # # Copyright (c) 1990-1996 Sam Leffler # Copyright (c) 1991-1996 Silicon Graphics, Inc. # HylaFAX is a trademark of Silicon Graphics, Inc. # # Permission to use, copy, modify, distribute, and sell this software and # its documentation for any purpose is hereby granted without fee, provided # that (i) the above copyright notices and this permission notice appear in # all copies of the software and related documentation, and (ii) the names of # Sam Leffler and Silicon Graphics may not be used in any advertising or # publicity relating to the software without the specific, prior written # permission of Sam Leffler and Silicon Graphics. # # THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND, # EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY # WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. # # IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR # ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND, # OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS, # WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF # LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE # OF THIS SOFTWARE. # # # Generic Class 2 modem configuration. # # EDIT THIS CONFIGURATION TO REFLECT YOUR SETUP # CountryCode: 49 AreaCode: 711 FAXNumber: +49.711.7880549 LongDistancePrefix: 0 InternationalPrefix: 00 DialStringRules: etc/dialrules ServerTracing: 0x00040 SessionTracing: 0 RecvFileMode: 0600 LogFileMode: 0600 DeviceMode: 0600 RingsBeforeAnswer: 0 SpeakerVolume: off GettyArgs: "-h %l dx_%s" LocalIdentifier: "HAGOS eG Stuttgart" TagLineFont: etc/lutRS18.pcf TagLineFormat: " Von %%l|%c|Seite %%p von %%t" QualifyTSI: etc/tsi PercentGoodLines: 90 MaxConsecutiveBadLines: 10 MaxRecvPages: 25 # # Modem-related stuff: should reflect modem command interface # and hardware connection/cabling (e.g. flow control). # ModemType: Class2 # use class 2 interface ModemRate: 38400 # lock rate for DCE-DTE communication ModemFlowControl: rtscts # default # ModemResetCmds: AT&FX3 ModemHardFlowCmd: AT&E4 # hardware flow control ModemSoftFlowCmd: AT&E5 # software flow control ModemSetupDTRCmd: AT&D3 # setup so DTR drop resets modem ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier (or not) ModemSetupAACmd: AT+FAA=1 # enable adaptive-answer in class 2 # # NB: some models get confused by the @ # ModemDialCmd: ATDT0,%s # Class2RecvDataTrigger: "\022" # character sent to modem to start recv #