> Where do I set this trigger 022? Answered elswhere, although a grep of the documentation would have found it. > Yes, the problem lies during the end of the page. Looking at the timing, it is being reported well after the end of page. > The modem picked up the incoming fax but at the end of the page, this EOL > error came out at the server side. At the sending side, it says Depending on whether the error is reported first by the modem or hylafax (the trace level isn't sufficient) this might not be a trigger problem. I was assuming that Hylafax was detecting the lack of EOL, but the length of timeout is rather high. If it is an RTC problem it is with the sender sending too few (none), not too many! > conmmunication error, please send again. The sender will have timed out waiting for confirmation (no reponse to MPS repeated 3 times, in Hylafax terminology).