I've had some good suggestions from Tim Rice here, but I still can't get a MultiTech MT3334ZDX to work reliably with Hylafax4.1Beta1 running on RedHat 6.2. Received pages will have various errors and "noise" (horizontal lines) on them. A few pages will come through perfectly. Many will be completely unreadable. I've checked the line. I've swapped modems. The problem appears to be in the modem or my configuration of it. Below is the config file for it. Anyone have any ideas. ################################## # Modem-related stuff: should reflect modem command interface # and hardware connection/cabling (e.g. flow control). # # ModemType: Class2 # use class 2 interface ModemRate: 38400 ModemFlowControl: rtscts ModemWaitForConnect: yes # wait for CONNECT on answer # ModemNoFlowCmd: AT&K0 # disable flow control cmd ModemHardFlowCmd: AT&K3 # hardware flow control ModemSoftFlowCmd: AT&K4 # software flow control ModemSetupDTRCmd: AT&D3 # setup so DTR drop resets modem ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier (or not) ModemSetupAACmd: AT+FAA=1 # enable adaptive-answer in class 2 # # NB: some models get confused by the @ # ModemDialCmd: ATDT%s@ # T for tone dialing, @ for silence # Class2RecvDataTrigger: "\022" # character sent to modem to start recv # # ModemSendFillOrder: LSB2MSB # as expected ModemRecvFillOrder: MSB2LSB # opposite of what makes sense Class2RecvDataTrigger: "\022" # a la 2388-B # Class2NRCmd: AT+FNR=1,1,1,0 # setup status reporting command # Class2XmitWaitForXON: no # Class2APQueryCmd: "" # AT+FAP=? not supported on this modem Class2NFLOCmd: AT+FLO=0 # Class 2: no flow control Class2SFLOCmd: AT+FLO=1 # Class 2: software flow control Class2HFLOCmd: AT+FLO=2 # Class 2: hardware flow control