HylaFAX The world's
most advanced open source fax server
|
|
[
Date Prev][
Date Next][
Thread Prev][
Thread Next]
[
Date Index]
[
Thread Index]
RE: MT3334ZDX Partial Success
Tim:
I added your lines to the MultiTech MT3334ZDX config file and reset it to
hardware handshaking. Unfortunately, I'm still getting scrambled faxes at
unpredictable times. Below is the modem part of the config file. Does
anything jump out at you?
Thanks for your help.
#############################
#
ModemType: Class2 # use class 2 interface
ModemRate: 38400
ModemFlowControl: rtscts
ModemWaitForConnect: yes # wait for CONNECT on answer
#
ModemNoFlowCmd: AT&K0 # disable flow control cmd
ModemHardFlowCmd: AT&K3 # hardware flow control
ModemSoftFlowCmd: AT&K4 # software flow control
ModemSetupDTRCmd: AT&D3 # setup so DTR drop resets modem
ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier (or not)
ModemSetupAACmd: AT+FAA=1 # enable adaptive-answer in class 2
#
# NB: some models get confused by the @
#
ModemDialCmd: ATDT%s@ # T for tone dialing, @ for silence
#
Class2RecvDataTrigger: "\022" # character sent to modem to start recv
#
#
ModemSendFillOrder: LSB2MSB # as expected
ModemRecvFillOrder: MSB2LSB # opposite of what makes sense
Class2RecvDataTrigger: "\022" # a la 2388-B
#
Class2NRCmd: AT+FNR=1,1,1,0 # setup status reporting command
#
Class2XmitWaitForXON: no
#
Class2APQueryCmd: "" # AT+FAP=? not supported on this
modem
Class2NFLOCmd: AT+FLO=0 # Class 2: no flow control
Class2SFLOCmd: AT+FLO=1 # Class 2: software flow control
Class2HFLOCmd: AT+FLO=2 # Class 2: hardware flow control