Hi!
told hylafax to use Servertracing and sessiontracing (262143) the maximum
possible.
here ist the output:
Apr 6 17:03:59 golem FaxQueuer[24016]: SUBMIT JOB 114
Apr 6 17:03:59 golem FaxQueuer[24016]: Purge stale UUCP lock
/var/lock/LCK..ttyI0
Apr 6 17:03:59 golem PageSend[24040]: logfacility = local6 (line 52)
Apr 6 17:03:59 golem PageSend[24040]: taglinefont = etc/lutRS18.pcf (line
53)
Apr 6 17:03:59 golem PageSend[24040]: taglineformat = %%l|%c|Seite %%p von
%%t (line 54)
Apr 6 17:03:59 golem PageSend[24040]: maxrecvpages = 25 (line 55)
Apr 6 17:03:59 golem PageSend[24040]: modemtype = Class1 (line 61)
Apr 6 17:03:59 golem PageSend[24040]: modemdialcmd = ATDT%s (line 79)
Apr 6 17:03:59 golem PageSend[24040]: modemresetcmds = AT&E9529071 (line
85)
Apr 6 17:03:59 golem PageSend[24040]: class1cmd = AT+FCLASS=1 (line 106)
Apr 6 17:03:59 golem PageSend[24040]: class1tcfresponsedelay = 75 (line
107)
Apr 6 17:03:59 golem PageSend[24040]: class1sendppmdelay = 75 (line 108)
Apr 6 17:03:59 golem PageSend[24040]: class1sendtcfdelay = 75 (line 109)
Apr 6 17:03:59 golem PageSend[24040]: class1trainingrecovery = 1500 (line
110)
Apr 6 17:03:59 golem PageSend[24040]: class1recvabortok = 200 (line 111)
Apr 6 17:03:59 golem PageSend[24040]: class1frameoverhead = 4 (line 112)
Apr 6 17:03:59 golem PageSend[24040]: class1recvidenttimer = 40000 (line
113)
Apr 6 17:03:59 golem PageSend[24040]: class1tcfmaxnonzero = 10 (line 114)
Apr 6 17:03:59 golem PageSend[24040]: class1tcfminrun = 1000 (line 115)
Apr 6 17:03:59 golem PageSend[24040]: Define AreaCode = "2624"
Apr 6 17:03:59 golem PageSend[24040]: Define CountryCode = "49"
Apr 6 17:03:59 golem PageSend[24040]: Define LongDistancePrefix = "0"
Apr 6 17:03:59 golem PageSend[24040]: Define InternationalPrefix = "00"
Apr 6 17:03:59 golem PageSend[24040]: Define Area = "2624"
Apr 6 17:03:59 golem PageSend[24040]: Define Country = "49"
Apr 6 17:03:59 golem PageSend[24040]: Define IDPrefix = "00"
Apr 6 17:03:59 golem PageSend[24040]: Define LDPrefix = "0"
Apr 6 17:03:59 golem PageSend[24040]: Define WS = " ^I"
Apr 6 17:03:59 golem PageSend[24040]: CanonicalNumber := [
Apr 6 17:03:59 golem PageSend[24040]: "#.*" = ""
Apr 6 17:03:59 golem PageSend[24040]: "[abcABC]" = "2"
Apr 6 17:03:59 golem PageSend[24040]: "[defDEF]" = "3"
Apr 6 17:03:59 golem PageSend[24040]: "[ghiGHI]" = "4"
Apr 6 17:03:59 golem PageSend[24040]: "[jklJKL]" = "5"
Apr 6 17:03:59 golem PageSend[24040]: "[mnoMNO]" = "6"
Apr 6 17:03:59 golem PageSend[24040]: "[prsPRS]" = "7"
Apr 6 17:03:59 golem PageSend[24040]: "[tuvTUV]" = "8"
Apr 6 17:03:59 golem PageSend[24040]: "[wxyWXY]" = "9"
Apr 6 17:03:59 golem PageSend[24040]: "[^+0-9]+" = ""
Apr 6 17:03:59 golem PageSend[24040]: "^00" = "+"
Apr 6 17:03:59 golem PageSend[24040]: "^0" = "+49"
Apr 6 17:03:59 golem PageSend[24040]: "^[^+]" = "+492624&"
Apr 6 17:03:59 golem PageSend[24040]: ]
Apr 6 17:03:59 golem PageSend[24040]: DialString := [
Apr 6 17:03:59 golem PageSend[24040]: "[- ^I.]+" = ""
Apr 6 17:03:59 golem PageSend[24040]: "[abcABC]" = "2"
Apr 6 17:03:59 golem PageSend[24040]: "[defDEF]" = "3"
Apr 6 17:03:59 golem PageSend[24040]: "[ghiGHI]" = "4"
Apr 6 17:03:59 golem PageSend[24040]: "[jklJKL]" = "5"
Apr 6 17:03:59 golem PageSend[24040]: "[mnoMNO]" = "6"
Apr 6 17:03:59 golem PageSend[24040]: "[prsPRS]" = "7"
Apr 6 17:03:59 golem PageSend[24040]: "[tuvTUV]" = "8"
Apr 6 17:03:59 golem PageSend[24040]: "[wxyWXY]" = "9"
Apr 6 17:03:59 golem PageSend[24040]: "^[+]49" = "0"
Apr 6 17:03:59 golem PageSend[24040]: "^[+]" = "00"
Apr 6 17:03:59 golem PageSend[24040]: ]
Apr 6 17:03:59 golem PageSend[24040]: MODEM set DTR OFF
Apr 6 17:03:59 golem PageSend[24040]: DELAY 2600 ms
Apr 6 17:04:02 golem PageSend[24040]: MODEM set DTR ON
Apr 6 17:04:02 golem PageSend[24040]: MODEM set baud rate: 19200 baud,
input flow NONE, output flow NONE
Apr 6 17:04:02 golem PageSend[24040]: MODEM flush i/o
Apr 6 17:04:02 golem PageSend[24040]: <-- [24:AT&E9529071E0V1Q0S0=0H0\r]
Apr 6 17:04:02 golem PageSend[24040]: --> [2:OK]
Apr 6 17:04:02 golem PageSend[24040]: <-- [12:ATS8=2S7=60\r]
Apr 6 17:04:02 golem PageSend[24040]: --> [2:OK]
Apr 6 17:04:02 golem PageSend[24040]: <-- [12:AT+FCLASS=?\r]
Apr 6 17:04:02 golem PageSend[24040]: --> [5:0,1,8]
Apr 6 17:04:02 golem PageSend[24040]: --> [2:OK]
Apr 6 17:04:02 golem PageSend[24040]: MODEM Supports "Data"
Apr 6 17:04:02 golem PageSend[24040]: MODEM Supports "Class 1"
Apr 6 17:04:02 golem PageSend[24040]: MODEM Supports "Voice"
Apr 6 17:04:02 golem PageSend[24040]: <-- [12:AT+FCLASS=0\r]
Apr 6 17:04:02 golem PageSend[24040]: --> [2:OK]
Apr 6 17:04:02 golem PageSend[24040]: MODEM: Mfr
Apr 6 17:04:02 golem PageSend[24040]: MODEM /
Apr 6 17:04:02 golem PageSend[24040]: <-- [5:ATM0\r]
Apr 6 17:04:02 golem PageSend[24040]: --> [2:OK]
Apr 6 17:04:02 golem PageSend[24040]: MODEM set parity: 7 bits, even parity
Apr 6 17:04:02 golem PageSend[24040]: STATE CHANGE: BASE -> RUNNING
Apr 6 17:04:02 golem PageSend[24040]: MODEM input buffering disabled
Apr 6 17:04:02 golem PageSend[24040]: Apply CanonicalNumber rules to
"01712092522"
Apr 6 17:04:02 golem PageSend[24040]: --> match rule "^0", result now
"+491712092522"
Apr 6 17:04:02 golem PageSend[24040]: --> return result "+491712092522"
Apr 6 17:04:02 golem PageSend[24040]: Apply CanonicalNumber rules to
"01712092522"
Apr 6 17:04:02 golem PageSend[24040]: --> match rule "^0", result now
"+491712092522"
Apr 6 17:04:02 golem PageSend[24040]: --> return result "+491712092522"
Apr 6 17:04:02 golem PageSend[24040]: SEND PAGE: JOB 114 DEST 01712092522
COMMID 00000158
Apr 6 17:04:36 golem PageSend[24040]: PAGE FAILED: Busy signal detected
I hope someone helps this more than my old postings.