Hello, I configured Hylafax as fax server My problem is: when polling specific machines with an USR Modem, communication breaks down using Class 1. Polling with Class 2 leads to absolutely no results. The Log file says: Class1: Remote is not T.4 compatible [log file attached] Class 2.0: Unspecified Phase C error, including too much delay between TCF and +FDR command (code 90) [log file not attached] A few months ago, there was a similar question posted to the mailing list, I tried the solution provided there but it did not work. I also tested same modem with another machine running WinNT 4.0 and Winfax 9.0 and the poll was succesful. As I am clueless about how to proceed and what to try, I would appreciate any help! Thanks very much in advance. Bye, Alex Hylafax: hylafax-v4.0pl2 Modem configuration: modem.config = usr-rts (Class 1, RTS/CTS, baud rate19200) file provided with Hylafax OS: FreeBSD 3.4-RC, gcc version 2.7.2.3 (and Linux 2.2.12) Modem: external 3com/USRobotics Sportster Flash x2 ATI0 provides Product Code 5601 ATI7 provides: Configuration Profile... Product type Germany External Product ID: 02566300 Options V32bis,V.34+,x2,V.90 Fax Options Class 1/Class 2.0 Voice Options Speakerphone, TAD Clock Freq 92.0Mhz EPROM 256k RAM 32k FLASH date 3/2/98 FLASH rev 11.1.17 DSP date 3/2/98 DSP rev 11.1.17 Product type Germany External Product ID: 02566300 Log File: [12911]: SESSION BEGIN 00000002 49190192247005 [12911]: SEND FAX: JOB 3 DEST 0190192247005 COMMID 00000002 [12911]: MODEM set DTR OFF [12911]: DELAY 2600 ms [12911]: MODEM set DTR ON [12911]: MODEM set baud rate: 19200 baud, input flow RTS/CTS, output flow RTS/CTS [12911]: MODEM flush i/o [12911]: <-- [17:ATE0V1Q0X4S0=0H0\r] [12911]: --> [2:OK] [12911]: <-- [32:ATS8=2S7=60&H1&I0&R2S13=1&D2&C1\r] [12911]: --> [2:OK] [12911]: <-- [12:AT+FCLASS=1\r] [12911]: --> [2:OK] [12911]: <-- [12:AT&H1&I0&R2\r] [12911]: --> [2:OK] [12911]: <-- [21:AT+FCLASS=0&H1&I0&R2\r] [12911]: --> [2:OK] [12911]: <-- [5:ATM0\r] [12911]: --> [2:OK] [12911]: MODEM input buffering enabled [12911]: <-- [12:AT+FCLASS=1\r] [12911]: --> [2:OK] [12911]: <-- [12:AT&H1&I0&R2\r] [12911]: --> [2:OK] [12911]: DIAL 0190192247005 [12911]: <-- [18:ATDT0190192247005\r] [12911]: --> [7:CONNECT] [12911]: MODEM input buffering disabled [12911]: --> [2:OK] [12911]: <-- [9:AT+FRH=3\r] [12911]: --> [7:CONNECT] [12911]: --> [2:OK] [12911]: REMOTE CSI "15" [12911]: <-- [9:AT+FRH=3\r] [12911]: --> [7:CONNECT] [12911]: --> [2:OK] [12911]: Remote is not T.4 compatible [12911]: SEND FAILED: Remote is not T.4 compatible [12911]: <-- [9:AT+FTH=3\r] [12911]: --> [7:CONNECT] [12911]: <-- data [3] [12911]: <-- data [2] [12911]: --> [2:OK] [12911]: MODEM input buffering enabled [12911]: <-- [5:ATH0\r] [12911]: --> [2:OK] [12911]: MODEM set DTR OFF [12911]: SESSION END -- A. Satow e-mail: a.satow@toba.rhein-neckar.de