![]() |
Hello, a few weeks ago I had same problems with my modem and hylafax. Now I used another Modem, but there is still a problem. I use RedHat 5.2 and hylafax4.0pl3 or hylafax4.1b1 (I tried both) with a Zyxel 1496e. When I want to send a fax: Aug 31 20:19:47.65: [ 8491]: DIAL ***** Aug 31 20:19:47.65: [ 8491]: <-- [12:ATDT*****\r] Aug 31 20:20:08.07: [ 8491]: --> [4:+FCO] Aug 31 20:20:08.07: [ 8491]: --> [26:+FCI:***** ] Aug 31 20:20:08.07: [ 8491]: REMOTE CSI "*****" Aug 31 20:20:08.07: [ 8491]: --> [20:+FIS:1,5,2,2,1,0,0,0] Aug 31 20:20:08.07: [ 8491]: --> [2:OK] Aug 31 20:20:08.07: [ 8491]: REMOTE best rate 14400 bit/s Aug 31 20:20:08.07: [ 8491]: REMOTE max page width 2432 pixels in 303 mm Aug 31 20:20:08.07: [ 8491]: REMOTE max unlimited page length Aug 31 20:20:08.07: [ 8491]: REMOTE best vres 7.7 line/mm Aug 31 20:20:08.07: [ 8491]: REMOTE best format 2-D MR Aug 31 20:20:08.07: [ 8491]: REMOTE best 0 ms/scanline Aug 31 20:20:08.07: [ 8491]: USE 14400 bit/s Aug 31 20:20:08.07: [ 8491]: USE 0 ms/scanline Aug 31 20:20:08.07: [ 8491]: <-- [5:ATH0\r] Aug 31 20:20:08.72: [ 8491]: --> [10:NO CARRIER] Aug 31 20:20:08.72: [ 8491]: MODEM No carrier Aug 31 20:20:08.72: [ 8491]: SESSION END Why is a ATH0 send ? Has anybody an idea ? I attached my config.ttyS1. Thanks Bastian -- Bastian Mathes, Tel. +49-451-53247
# $Id: zyxel-1496e-2.0,v 1.19 1996/06/24 02:58:44 sam Rel $ # # HylaFAX Facsimile Software # # Copyright (c) 1990-1996 Sam Leffler # Copyright (c) 1991-1996 Silicon Graphics, Inc. # HylaFAX is a trademark of Silicon Graphics, Inc. # # Permission to use, copy, modify, distribute, and sell this software and # its documentation for any purpose is hereby granted without fee, provided # that (i) the above copyright notices and this permission notice appear in # all copies of the software and related documentation, and (ii) the names of # Sam Leffler and Silicon Graphics may not be used in any advertising or # publicity relating to the software without the specific, prior written # permission of Sam Leffler and Silicon Graphics. # # THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND, # EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY # WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. # # IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR # ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND, # OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS, # WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF # LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE # OF THIS SOFTWARE. # # # Configuration for a ZyXEL-1496E or 2864 w/ Class 2.0 firmware. # Firmware revisions from 6.12 on should work for the 1496E; for # the 2864 you must have firmware rev 0.07 or later. # # This configuration file sets up the ZyXEL to run at 38.4 for # both sending and receiving. RTS/CTS flow control is used on # the tty port--you probably shouldn't use XON/XOFF. Note that # on an SGI system the getty speed is the following non-standard # gettydefs entry: # # dx_38400# B38400 # B38400 SANE TAB3 HUPCL #\r\n\n$HOSTNAME login: #dx_38400 # # CountryCode: 49 AreaCode: 451 FAXNumber: +49.451.53247 LongDistancePrefix: 0 InternationalPrefix: 00 DialStringRules: "etc/dialrules" ServerTracing: 1 SessionTracing: 11 RecvFileMode: 0600 LogFileMode: 0600 DeviceMode: 0600 RingsBeforeAnswer: 1 SpeakerVolume: low GettyArgs: "-s %s %l" LocalIdentifier: "Bastian Mathes" TagLineFont: etc/lutRS18.pcf TagLineFormat: "Von %%l|%c|Seite %%p von %%t" NoCarrierRetrys: 3 MaxRecvPages: 25 # # # Modem-related stuff: should reflect modem command interface # and hardware connection/cabling (e.g. flow control). # ModemType: Class2.0 # use class 2.0 interface ModemRate: 38400 # 38.4 works fine ModemFlowControl: rtscts # default # ModemNoFlowCmd: AT&H0 # disable flow control ModemHardFlowCmd: AT&H3 # hardware flow control ModemSoftFlowCmd: AT&H4 # software flow control ModemSetupDTRCmd: AT&D2 # DTR off causes modem to hang up ModemSetupDCDCmd: AT&C1 # DCD tracks carrier # ModemSetupAACmd: AT+FAA=1 # enable in current class # # Additional reset commands: # # &B1 DTE-DCE rate is fixed at DTE setting # &N0 Auto-negotiate highest possible DCE-DCE link rate # &S0 DSR always on # *F0 Deny remote configuration # S18=2 Receive at 38400 # S38.3=1 DCD on/off sequence follows UNIX standard; also # fix receiving baud rate at S18 value # S39=0 (avoid Class 2 compatibility hacks) # ModemResetCmds: AT&B1&N0&S0*F0S18=2S38.3=1S39=0 # ModemDialCmd: ATDT%s # no '@' 'cuz then busy not recognized NoCarrierRetrys: 3 # retry 3 times on no carrier # ModemSetVolumeCmd: "ATM0 ATM1L1 ATM1L3 ATM1L5 ATM1L7" # # Caller ID configuration setup. # #QualifyCID: etc/cid # CID access control list file #CIDNumber: "CALLER NUMBER: " # pattern string for phone number info #CIDName: "CALLER NAME: " # pattern string for identity info # PagerSetupCmds: AT&K0&N15 # use V.22 at 1200 bps (PageNet) # # Rev 6.1x firmware have a bug in the ECM support so # explicitly disable it's use. To re-enable its use just # comment out the following line. # Class2DCCQueryCmd: "!(0,1),(0-5),(0-4),(0-2),(0,1),(0),(0),(0-7)"