HylaFax and Diamond SupraExpress 56e PRO -- cannot receive any fax



Hello,

I recently managed to install HylaFax 4.0pl2 on my 2.0.36 Linuxbox
with egcs-1.1.1 and was succesfull in sending a fax out with my
Diamond SupraExpress 56e PRO.  But I am not able to receive any fax.
And because I have only one telephone line it is very difficult to
test.=20

Support from Diamond wasn't very helpful (Oh, Linux? That's not our
game ...), the AT-Doku for the included Rockwell Chips (RCV56HCF) is
very outdated and doesn't know anything about Class 2 Fax commands.

After I changed the tracelevels to 527 there are the following lines
showing up in the log-file:

Jun 22 22:07:57.53: [ 137]: SESSION BEGIN 00000006 49
Jun 22 22:07:57.54: [ 137]: <-- [4:ATA\r]
Jun 22 22:07:58.88: [ 137]: --> [3:FAX]
Jun 22 22:07:58.88: [ 137]: MODEM set baud rate: 19200 baud
                            (flow control unchanged)
Jun 22 22:07:58.89: [ 137]: MODEM set baud rate: 19200 baud,
                            input flow XON/XOFF, output flow XON/XOFF
Jun 22 22:07:58.89: [ 137]: ANSWER: FAX CONNECTION
Jun 22 22:07:58.89: [ 137]: MODEM input buffering enabled
Jun 22 22:07:58.90: [ 137]: RECV FAX: begin
Jun 22 22:10:58.99: [ 137]: MODEM TIMEOUT: reading line from modem
Jun 22 22:10:59.02: [ 137]: REMOTE HANGUP: Unspecified Receive Phase B
                            error (code 70)
Jun 22 22:10:59.02: [ 137]: RECV FAX: Unspecified Receive Phase B error
Jun 22 22:10:59.03: [ 137]: RECV FAX: end
Jun 22 22:10:59.03: [ 137]: SESSION END



Yes, I did read the FAQ and the SDB (Suse Support Database). They both=20
mention this error, with the solution to change ModemRecvFillOrder
from "LSB2MSB" to "MSB2LSB" -- but my config.modem have had the
obscure order.  Sure, I changed it, but without any effect.

Here is the modem related stuff from config.modem.  With this
confiuration I have received the log showed above.

#
ModemType:=09=09Class2=09=09# use class 2 interface
ModemRate:=09=0938400
ModemFlowControl:=09rtscts=09=09# default
#
#ModemResetCmds:=09AT&F2=09=09# what you want for a Supra
ModemNoFlowCmd:=09=09AT&K=09=09# disable flow control cmd
ModemHardFlowCmd:=09AT&K3=09=09# hardware flow control cmd
ModemSoftFlowCmd:=09AT&K4=09=09# software flow control cmd
ModemSetupDTRCmd:=09AT&D3=09=09# DTR off causes modem to reset
#ModemSetupDTRCmd:=09AT&D2S25=3D1S38=3D0=09# Dynalink 1414VE needs this
ModemSetupDCDCmd:=09AT&C1=09=09# DCD follows carrier
ModemSetupAACmd:=09AT+FAA=3D1+FCLASS=3D0 # enable in current class
#
ModemSendFillOrder:=09LSB2MSB=09=09# as expected
ModemRecvFillOrder:=09MSB2LSB=09=09# opposite of what makes sense
#ModemRecvFillOrder:=09LSB2MSB=09=09# the normal way
#
ModemAnswerFaxBeginCmd:=09"<19200><xon>"=09# modem switches on fax receiv=
e
#
# Caller ID configuration setup for Supra.
#
#QualifyCID:=09=09etc/cid=09=09# CID access control list file
#CIDNumber:=09=09"NMBR =3D "=09# pattern string for phone number info
#CIDName:=09=09"NAME =3D "=09# pattern string for identity info


Could you please help me?

Yours
  Uwe Koloska


--
mailto:koloska@rcs.urz.tu-dresden.de
http://rcswww.urz.tu-dresden.de/~koloska/
--                                    --
right now the web page is in german only
but this will change as time goes by ;-)