HylaFAX The world's
most advanced open source fax server
|
|
[
Date Prev][
Date Next][
Thread Prev][
Thread Next]
[
Date Index]
[
Thread Index]
Re: retrain negative/resend?
Hello,
here are my results of testing a Zyxel 1496E und am Modem with Rockwell
288 chip.
I hope someone can help me.
Thanks
Stephan Bauer
Zyxel 1496E:
Feb 09 22:33:52.82: [ 476]: <-- data [9]
Feb 09 22:33:52.82: [ 476]: SEND end page
Feb 09 22:33:52.82: [ 476]: SEND send EOP (no more pages or documents)
Feb 09 22:33:52.82: [ 476]: <-- data [2]
Feb 09 22:34:19.03: [ 476]: --> [5:ERROR]
Feb 09 22:34:19.03: [ 476]: SEND recv RTN (retrain negative)
Feb 09 22:34:19.03: [ 476]: <-- [7:AT+FDT\r]
Feb 09 22:34:24.73: [ 476]: --> [20:+FCS:0,3,0,2,0,0,0,5]
Rockwell 288:
Feb 09 22:51:50.88: [ 742]: <-- data [2]
Feb 09 22:51:50.88: [ 742]: SEND end page
Feb 09 22:52:15.73: [ 742]: --> [2:OK]
Feb 09 22:52:15.73: [ 742]: SEND send EOP (no more pages or documents)
Feb 09 22:52:15.73: [ 742]: <-- [9:AT+FET=2\r]
Feb 09 22:52:18.60: [ 742]: --> [8:+FPTS: 3]
Feb 09 22:52:20.19: [ 742]: --> [8:+FHNG: 0]
Feb 09 22:52:20.19: [ 742]: REMOTE HANGUP: Normal and proper end of
connection (code 0)
Feb 09 22:52:20.19: [ 742]: SEND recv RTP (retrain positive)
Config Zyxel:
ModemType: Class2.0 # use
class 2.0 interface
ModemRate: 38400 #
38.4 works fine
ModemFlowControl: rtscts #
default
ModemNoFlowCmd: AT&H0 # disable flow
control
ModemHardFlowCmd: AT&H3 # hardware flow
control
ModemSoftFlowCmd: AT&H4 # software flow
control
ModemSetupDTRCmd: AT&D2 # DTR off causes
modem to hang up
ModemSetupDCDCmd: AT&C1 # DCD tracks carrier
ModemSetupAACmd: AT+FAA=1 # enable in current
class
ModemResetCmds: AT&B1&N0&S0*F0S18=2S38.3=1S39=0
ModemDialCmd: "ATX0\nATDT0%s" # no '@' 'cuz then busy
not recognized
NoCarrierRetrys: 3 #
retry 3 times on no carrier
ModemSetVolumeCmd: "ATM0 ATM1L1 ATM1L3 ATM1L5 ATM1L7"
Class2DCCQueryCmd: "!(0,1),(0-5),(0-4),(0-2),(0),(0),(0),(0-7)"
Config Rockwell 288:
ModemType: Class2 # use
class 2 interface
ModemRate: 38400
ModemFlowControl: rtscts # default
ModemDialCmd: "ATX0\nATDT0%s" # no '@' 'cuz then busy
not recognized
ModemNoFlowCmd: AT&K0 # disable flow
control cmd
ModemSoftFlowCmd: AT&K4 # software flow
control cmd
ModemHardFlowCmd: AT&K3 # hardware flow
control cmd
ModemSetupDTRCmd: AT&D3 # DTR off causes modem
to reset
ModemSetupDCDCmd: AT&C1 # DCD follows carrier
ModemSetupAACmd: AT+FAA=1 # enable adaptive-answer
in Class 2
ModemSendFillOrder: LSB2MSB # as expected
ModemRecvFillOrder: MSB2LSB # opposite of what
makes sense
ModemAnswerFaxBeginCmd: "<19200><xon>" # modem switches on fax receive
Class2RecvDataTrigger: "\022" # character
sent to modem to start recv