Re: EOP trouble
I wonder if this could actually be caused by the ghostscript or something
like that. I have received these errors as well and wonder if this may be
the cause?
Keith
At 10:37 AM 2/1/99 -0500, you wrote:
>I've seen these types of errors too. What usually happens is that someone
>will call me and complain that they get 3 copies of every fax I send. When I
>look at the logs, it looks like their fax machine simply hangs up after
>receiving the last page of the fax instead of doing the last little bit of
>handshaking. I suspect a modification to the source code to ignore errors
>after the last page is sent is needed.
>
>-----Original Message-----
>From: owner-flexfax@celestial.com [mailto:owner-flexfax@celestial.com]
>On Behalf Of Peter Bär
>Sent: Friday, January 29, 1999 8:18 PM
>To: flexfax@sgi.com
>Subject: flexfax: EOP trouble
>
>
>More and more of these "No response to EOP or MSP" problem reports
>appear on this list, as it seems. Normally USR/3Com are blamed for
>this, as their Class 2.0 implementation is non-standard.
>However, especially in the last few weeks weeks several users of
>other modems (Non-3Com) have reported similar trouble.
>
>Myself, I replaced my USR 56k Voice Fax Modem, thinking that this
>would cure the problem. Now I have a Maxtech Net Pacer 56k Voice
>Fax Modem. It is Class 2, so I thought, my troubles were over, now.
>(A different make and a different protocol should really improve
>things, I thought ;-)).
>
>However, nothing changed. With certain fax machines I am still
>having trouble. Not with fax modems, just with conventional (paper)
>fax machines.
>
>After the transmission of the last page (even if there is only one)
>I get this error message.
>
>No response to EOP repeated 3 times.
>
>What does that actually mean? And what is it that causes the different
>behaviour of fax machines (error) and fax modems (no problem)? I should
>mention that the problem occurs with *old* fax machines. With newer
>models normally everything is ok.
>
>Any tips and hints and explanations will be greatly appreciated!
>
> Regards
> Peter
>
>------------------------------------------------------------------------
>>>> FAX TRANSMISSION LOG <<<
>****************************
>n 30 00:39:56 orion7 FaxQueuer[156]: SUBMIT JOB 7
>Jan 30 00:39:56 orion7 FaxQueuer[156]: JOB 7 (active dest +49109809519522222
>pri
> 127 tts 0:00 killtime 2:59:00): PREPARE START
>Jan 30 00:39:56 orion7 FaxQueuer[1747]: JOB 7 (active dest
>+49109809519522222 pr
>i 127 tts 0:00 killtime 2:59:00): CONVERT DOCUMENT: bin/ps2fax -o
>docq/doc6.ps;0
>0 -r 98 -w 1728 -l 297 -m 30 -1 docq/doc6.ps.7
>Jan 30 00:39:56 orion7 HylaFAX[1749]: sendq/q6: line 51: Null or missing
>number
>in job request
>Jan 30 00:39:58 orion7 FaxQueuer[156]: JOB 7 (active dest +49109809519522222
>pri
> 127 tts 0:00 killtime 2:58:58): PREPARE DONE
>Jan 30 00:39:58 orion7 FaxQueuer[156]: JOB 7 (active dest +49109809519522222
>pri
> 127 tts 0:00 killtime 2:58:58): CMD START /usr/lib/fax/faxsend -m modem
>sendq/q
>7 (PID 1752)
>Jan 30 00:40:00 orion7 FaxSend[1752]: MODEM set DTR OFF
>Jan 30 00:40:00 orion7 FaxSend[1752]: DELAY 2600 ms
>Jan 30 00:40:00 orion7 FaxGetty[170]: ANSWER: Can not lock modem device
>Jan 30 00:40:01 orion7 kernel: lp1 out of paper
>Jan 30 00:40:02 orion7 FaxSend[1752]: MODEM set DTR ON
>Jan 30 00:40:02 orion7 FaxSend[1752]: MODEM set baud rate: 38400 baud, input
>flo
>w RTS/CTS, output flow RTS/CTS
>Jan 30 00:40:02 orion7 FaxSend[1752]: MODEM flush i/o
>Jan 30 00:40:02 orion7 FaxSend[1752]: <-- [15:ATE0V1Q0S0=0H0\r]
>Jan 30 00:40:02 orion7 FaxSend[1752]: --> [14:ATE0V1Q0S0=0H0]
>Jan 30 00:40:02 orion7 FaxSend[1752]: --> [2:OK]
>Jan 30 00:40:02 orion7 FaxSend[1752]: <-- [21:ATS8=2S7=60&K3&D3&C1\r]
>Jan 30 00:40:02 orion7 FaxSend[1752]: --> [2:OK]
>Jan 30 00:40:02 orion7 FaxSend[1752]: <-- [12:AT+FCLASS=?\r]
>Jan 30 00:40:03 orion7 FaxSend[1752]: --> [9:0,1,2,1.0]
>Jan 30 00:40:03 orion7 FaxSend[1752]: --> [2:OK]
>Jan 30 00:40:03 orion7 FaxSend[1752]: <-- [12:AT+FCLASS=2\r]
>Jan 30 00:40:03 orion7 FaxSend[1752]: --> [2:OK]
>Jan 30 00:40:03 orion7 FaxSend[1752]: <-- [9:AT+FMFR?\r]
>Jan 30 00:40:03 orion7 FaxSend[1752]: --> [20:ROCKWELL ]
>Jan 30 00:40:03 orion7 FaxSend[1752]: --> [2:OK]
>Jan 30 00:40:03 orion7 FaxSend[1752]: <-- [9:AT+FMDL?\r]
>Jan 30 00:40:03 orion7 FaxSend[1752]: --> [13:AC/K56^I^I ]
>Jan 30 00:40:03 orion7 FaxSend[1752]: --> [2:OK]
>Jan 30 00:40:03 orion7 FaxSend[1752]: <-- [9:AT+FREV?\r]
>Jan 30 00:40:03 orion7 FaxSend[1752]: --> [17:V2.077-V90_2M_DLS]
>Jan 30 00:40:03 orion7 FaxSend[1752]: --> [2:OK]
>Jan 30 00:40:03 orion7 FaxSend[1752]: <-- [10:AT+FDCC=?\r]
>Jan 30 00:40:03 orion7 FaxSend[1752]: -->
>[35:(0,1),(0-5),(0-2),(0-2),0,0,0,(0-7
>)]
>Jan 30 00:40:03 orion7 FaxSend[1752]: --> [2:OK]
>Jan 30 00:40:03 orion7 FaxSend[1752]: <-- [9:AT+FCQ=?\r]
>Jan 30 00:40:03 orion7 FaxSend[1752]: --> [1:0]
>Jan 30 00:40:03 orion7 FaxSend[1752]: --> [2:OK]
>Jan 30 00:40:03 orion7 FaxSend[1752]: <-- [9:AT+FAP=?\r]
>Jan 30 00:40:03 orion7 FaxSend[1752]: --> [5:ERROR]
>Jan 30 00:40:03 orion7 FaxSend[1752]: <-- [10:AT+FSPL=?\r]
>Jan 30 00:40:04 orion7 FaxSend[1752]: --> [3:0,1]
>Jan 30 00:40:04 orion7 FaxSend[1752]: --> [2:OK]
>Jan 30 00:40:04 orion7 FaxSend[1752]: <-- [12:AT+FCLASS=2\r]
>Jan 30 00:40:04 orion7 FaxSend[1752]: --> [2:OK]
>Jan 30 00:40:04 orion7 FaxSend[1752]: <-- [10:AT+FTBC=0\r]
>Jan 30 00:40:04 orion7 FaxSend[1752]: --> [2:OK]
>Jan 30 00:40:04 orion7 FaxSend[1752]: <-- [10:AT+FBOR=0\r]
>Jan 30 00:40:04 orion7 FaxSend[1752]: --> [2:OK]
>Jan 30 00:40:04 orion7 FaxSend[1752]: <-- [13:AT+FPHCTO=30\r]
>Jan 30 00:40:04 orion7 FaxSend[1752]: --> [2:OK]
>Jan 30 00:40:04 orion7 FaxSend[1752]: <-- [24:AT+FDCC=1,5,2,2,0,0,0,0\r]
>Jan 30 00:40:04 orion7 FaxSend[1752]: --> [2:OK]
>Jan 30 00:40:04 orion7 FaxSend[1752]: MODEM ROCKWELL
>AC/K56/V2.077-V90_2M_DLS
>Jan 30 00:40:04 orion7 FaxSend[1752]: <-- [5:ATM0\r]
>Jan 30 00:40:04 orion7 FaxSend[1752]: --> [2:OK]
>Jan 30 00:40:04 orion7 FaxSend[1752]: MODEM input buffering disabled
>Jan 30 00:40:04 orion7 FaxSend[1752]: SEND FAX: JOB 7 DEST 0109809519522222
>COMM
>ID 00000029
>Jan 30 00:40:11 orion7 kernel: lp1 out of paper
>Jan 30 00:40:31 orion7 last message repeated 2 times
>Jan 30 00:40:32 orion7 HylaFAX[1749]: sendq/q6: line 51: Null or missing
>number
>in job request
>Jan 30 00:40:41 orion7 kernel: lp1 out of paper
>Jan 30 00:40:51 orion7 kernel: lp1 out of paper
>Jan 30 00:40:54 orion7 FaxQueuer[156]: JOB 7 (active dest +49109809519522222
>pri
> 127 tts 0:00 killtime 2:58:02): CMD DONE: exit status 0
>Jan 30 00:40:54 orion7 FaxQueuer[156]: JOB 7 (sleeping dest
>+49109809519522222 p
>ri 126 tts 0:00 killtime 2:58:02): SEND INCOMPLETE: requeue for 4:59; No
>respons
>e to EOP repeated 3 times
>Jan 30 00:40:54 orion7 FaxQueuer[156]: NOTIFY: bin/notify "sendq/q7"
>"requeued"
>"" "00:45"
>Jan 30 00:40:57 orion7 HylaFAX[1749]: sendq/q6: line 51: Null or missing
>number
>in job request
>Jan 30 00:41:00 orion7 FaxGetty[170]: MODEM set DTR OFF
>Jan 30 00:41:00 orion7 FaxGetty[170]: DELAY 2600 ms
>Jan 30 00:41:01 orion7 kernel: lp1 out of paper
>Jan 30 00:41:02 orion7 FaxGetty[170]: MODEM set DTR ON
>Jan 30 00:41:02 orion7 FaxGetty[170]: MODEM set baud rate: 38400 baud, input
>flo
>w RTS/CTS, output flow RTS/CTS
>Jan 30 00:41:02 orion7 FaxGetty[170]: MODEM flush i/o
>Jan 30 00:41:02 orion7 FaxGetty[170]: <-- [15:ATE0V1Q0S0=0H0\r]
>Jan 30 00:41:03 orion7 FaxGetty[170]: --> [2:OK]
>Jan 30 00:41:03 orion7 FaxGetty[170]: <-- [21:ATS8=2S7=60&K3&D3&C1\r]
>Jan 30 00:41:03 orion7 FaxGetty[170]: --> [2:OK]
>Jan 30 00:41:03 orion7 FaxGetty[170]: <-- [12:AT+FCLASS=?\r]
>Jan 30 00:41:03 orion7 FaxGetty[170]: --> [9:0,1,2,1.0]
>Jan 30 00:41:03 orion7 FaxGetty[170]: --> [2:OK]
>Jan 30 00:41:03 orion7 FaxGetty[170]: <-- [12:AT+FCLASS=2\r]
>Jan 30 00:41:03 orion7 FaxGetty[170]: --> [2:OK]
>Jan 30 00:41:03 orion7 FaxGetty[170]: <-- [9:AT+FMFR?\r]
>Jan 30 00:41:03 orion7 FaxGetty[170]: --> [20:ROCKWELL ]
>Jan 30 00:41:03 orion7 FaxGetty[170]: --> [2:OK]
>Jan 30 00:41:03 orion7 FaxGetty[170]: <-- [9:AT+FMDL?\r]
>Jan 30 00:41:03 orion7 FaxGetty[170]: --> [13:AC/K56^I^I ]
>Jan 30 00:41:03 orion7 FaxGetty[170]: --> [2:OK]
>Jan 30 00:41:03 orion7 FaxGetty[170]: <-- [9:AT+FREV?\r]
>Jan 30 00:41:03 orion7 FaxGetty[170]: --> [17:V2.077-V90_2M_DLS]
>Jan 30 00:41:03 orion7 FaxGetty[170]: --> [2:OK]
>Jan 30 00:41:03 orion7 FaxGetty[170]: <-- [10:AT+FDCC=?\r]
>Jan 30 00:41:03 orion7 FaxGetty[170]: -->
>[35:(0,1),(0-5),(0-2),(0-2),0,0,0,(0-7
>)]
>Jan 30 00:41:03 orion7 FaxGetty[170]: --> [2:OK]
>Jan 30 00:41:03 orion7 FaxGetty[170]: <-- [9:AT+FCQ=?\r]
>Jan 30 00:41:03 orion7 FaxGetty[170]: --> [5:ERROR]
>Jan 30 00:41:03 orion7 FaxGetty[170]: <-- [10:AT+FSPL=?\r]
>Jan 30 00:41:03 orion7 FaxGetty[170]: --> [3:0,1]
>Jan 30 00:41:03 orion7 FaxGetty[170]: --> [2:OK]
>Jan 30 00:41:03 orion7 FaxGetty[170]: <-- [12:AT+FCLASS=2\r]
>Jan 30 00:41:03 orion7 FaxGetty[170]: --> [2:OK]
>Jan 30 00:41:03 orion7 FaxGetty[170]: <-- [10:AT+FTBC=0\r]
>Jan 30 00:41:03 orion7 FaxGetty[170]: --> [2:OK]
>Jan 30 00:41:03 orion7 FaxGetty[170]: <-- [10:AT+FBOR=0\r]
>Jan 30 00:41:03 orion7 FaxGetty[170]: --> [2:OK]
>Jan 30 00:41:03 orion7 FaxGetty[170]: <-- [13:AT+FPHCTO=30\r]
>Jan 30 00:41:03 orion7 FaxGetty[170]: --> [2:OK]
>Jan 30 00:41:03 orion7 FaxGetty[170]: <-- [24:AT+FDCC=1,5,2,2,0,0,0,0\r]
>Jan 30 00:41:03 orion7 FaxGetty[170]: --> [2:OK]
>Jan 30 00:41:03 orion7 FaxGetty[170]: MODEM ROCKWELL
>AC/K56/V2.077-V90_2M_DLS
>Jan 30 00:41:03 orion7 FaxGetty[170]: <-- [5:ATM0\r]
>Jan 30 00:41:03 orion7 FaxGetty[170]: --> [2:OK]
>Jan 30 00:41:03 orion7 FaxGetty[170]: <-- [9:AT+FCR=1\r]
>Jan 30 00:41:03 orion7 FaxGetty[170]: --> [2:OK]
>Jan 30 00:41:03 orion7 FaxGetty[170]: <-- [18:AT+FLID="Orion 7"\r]
>Jan 30 00:41:03 orion7 FaxGetty[170]: --> [2:OK]
>Jan 30 00:41:03 orion7 FaxGetty[170]: <-- [18:AT+FAA=1+FCLASS=0\r]
>Jan 30 00:41:03 orion7 FaxGetty[170]: --> [2:OK]
>Jan 30 00:41:03 orion7 FaxGetty[170]: MODEM input buffering disabled
>Jan 30 00:41:11 orion7 kernel: lp1 out of paper
>Jan 30 00:41:14 orion7 HylaFAX[1749]: sendq/q6: line 51: Null or missing
>number
>in job request
>
>----------------------------------------------------------------------------
>>>> MODEM CONFIGURATION <<<
>***************************
>CountryCode: 49
>AreaCode: 911
>FAXNumber: +49.911.731851
>LongDistancePrefix: 0
>InternationalPrefix: 00
>DialStringRules: "etc/dialrules"
>ServerTracing: 527
>SessionTracing: 527
>RecvFileMode: 0644
>LogFileMode: 0600
>DeviceMode: 0666
>RingsBeforeAnswer: 4
>SpeakerVolume: off
>GettyArgs: "-r -b -s %s %l"
>LocalIdentifier: "Orion 7"
>TagLineFont: etc/lutRS18.pcf
>TagLineFormat: "From %%l|%c|Page %%p of %%t"
>MaxRecvPages: 25
>#
># Modem-related stuff: should reflect modem command interface
># and hardware connection/cabling (e.g. flow control).
>#
>ModemType: Class2 # use class 2 interface
>ModemRate: 38400
>ModemFlowControl: rtscts # default
>#
>#ModemResetCmds: AT&F2 # what you want for a Supra
>ModemNoFlowCmd: AT&K # disable flow control cmd
>ModemHardFlowCmd: AT&K3 # hardware flow control cmd
>ModemSoftFlowCmd: AT&K4 # software flow control cmd
>ModemSetupDTRCmd: AT&D3 # DTR off causes modem to reset
>#ModemSetupDTRCmd: AT&D2S25=1S38=0 # Dynalink 1414VE needs this
>ModemSetupDCDCmd: AT&C1 # DCD follows carrier
>ModemSetupAACmd: AT+FAA=1+FCLASS=0 # enable in current class
>#
>ModemSendFillOrder: LSB2MSB # as expected
>ModemRecvFillOrder: MSB2LSB # opposite of what makes sense
>#
>ModemAnswerFaxBeginCmd: "<19200><xon>" # modem switches on fax receive
>#
># Caller ID configuration setup for Supra.
>#
>#QualifyCID: etc/cid # CID access control list file
>#CIDNumber: "NMBR = " # pattern string for phone number
>info
>#CIDName: "NAME = " # pattern string for identity info
>
>
>
>--
>---------------------------------------------------------------------
> The manual said the software required Windows 95
> or better, so I installed Linux.
> >>> comet.friend@gmx.net <<<
>---------------------------------------------------------------------
>
Keith Elder
Affordable Computers, Inc.
1070 Rosewood
Ann Arbor, MI 48104
voice: 734-761-1698 X.109
fax: 734-669-8485
email: keith@acinc.com
Shop Online at: http://www.acinc.com
Specials: Custom built NOTEBOOKS starting at $1259.00! IBM P70 17inch .26
1600x1200 res. monitor for only $219.00! Laptops Laptops Laptops, come
visit our web site for your next purchase! Laptops as low as $199!