Re: AutoAnswer
Eliminate the Obvious Dept: sounds like autoanswer is off? AA light will
always blink on a ring, that doesn't mean the modem is set to auto-answer.
Connect to the modem and set:
ATS0=1&W
On Thu, 19 Nov 1998, Eric Smith wrote:
> Apologies for the repeat but i forgot to include my config file:
>
> I have a USR 33.6 Faxmodem. I have had many problems with config and here is a
> file that sends faxes ok. The question is what can I do to get the modem to
> autoanswer. It has worked for me in the past but I cannot seem to get it
> working now. faxgetty is running.
> The AA light just comes on but does not go off hook.
> if I type faxanswer cua0, then it will answer.
> Thank you
>
> Eric Smith
>
>
> # $Id: usr-rts,v 1.6 1996/06/24 02:58:43 sam Rel $
> #
> # Configuration for using the Class 1 command interface with
> # a USR Courier or Sportster modem and RTS/CTS flow control.
> #
> # CONFIG:CLASS1:1444:.*:RTSCTS: Manufacturer=USRobotics Model=Courier/Sportster
> # CONFIG:CLASS1:1445:.*:RTSCTS: Manufacturer=USRobotics Model=Courier/Sportster
> # CONFIG:CLASS1:2886:.*:RTSCTS: Manufacturer=USRobotics Model=Courier/Sportster
> # CONFIG:CLASS1:3366:.*:RTSCTS: Manufacturer=USRobotics Model=Courier
> #
> # BEGIN-SERVER
> # END-SERVER
> #
> # Modem-related stuff: should reflect modem command interface
> # and hardware connection/cabling (e.g. flow control).
> #
> ModemType: Class1 # use class 1 interface
> ModemRate: 38400 # max rate for DCE-DTE communication
> ModemFlowControl: rtscts # hardware flow control
> #
> ModemSetupDTRCmd: ATS13=1&D2 # setup so DTR drop resets modem
> ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier (or not)
> ModemNoFlowCmd: AT&H0&I0&R1 # setup modem for no flow control
> ModemHardFlowCmd: AT&H1&I0&R2 # setup modem for hardware flow control
> ModemSoftFlowCmd: AT&H2&I2&R1 # setup modem for software flow control
> ModemResultCodesCmd: ATQ0X4 # enable result codes
> #
> ModemMfrQueryCmd: !USR
> ModemModelQueryCmd: ATI3
> ModemRevQueryCmd: ATI7 # XXX, returns a multi-line result
> #
> # When AT+FCLASS=1 is issued the modem automatically switches
> # to software flow control; these parameters let the fax software
> # reset flow control as needed after entering Class 1.
> #
> Class1NFLOCmd: AT&H0&I0&R1 # setup modem for no flow control
> Class1HFLOCmd: AT&H1&I0&R2 # setup modem for hardware flow control
> Class1SFLOCmd: "" # modem does this automatically
> #
> # The remainder of this configuration is included so that the
> # modem "idles" in Class 0 while not sending or receiving facsimile.
>
> #Eric fiddled here unsuccesfully to get AA to work
> #ModemSetupAACmd: AT+FCLASS=0&H1&I0&R2 # leave modem in class 0
> #ModemAnswerFaxCmd: ATA # if null reads ModemAnswerCmd
> #ModemAnswerCmd: AT+FCLASS=1&H1&I0&R2A # force RTS/CTS after change
> #ModemAnswerCmd: ATA
> #RingsBeforeAnswer: 1
-------------------------------------