On Fri, 11 Jul 1997, Alex Ongena wrote: [snip] > so I think it is my Modem setup ... but as far as I can check, this > should be Ok. (it is not my modem, I tested 3 different modems: MT2834ZDX > MT2834ZDXi, GVC 28800 (Rockwell Chipset)) Most Rockwell chips require the following entry in config.tty*: ModemAnswerFaxBeginCmd: "<19200><xon>" To lock the line rate to 19200 and flow-control to xon-xoff (which I suspect is your problem). Cheers. -- Jonathan Chen e-mail : jonc@pinnacle.co.nz Pinnacle Software Ltd Voice : +64.9.415.4460 Auckland, New Zealand Fax : +64.9.415.4250